Air conditioning in non-domestic buildings
In June 2016, BRE published Study on Energy Use by Air-Conditioning: Final Report, BRE Client Report for the Department of Energy & Climate Change, HPR218-1001.
The report sheds important light on the electricity use of air conditioning in UK offices and retail environments. It presents the findings of a two-year study commissioned by the Department of Energy and Climate Change (DECC - now subsumed within the newly-formed Department of Business, Energy and Industrial Strategy) providing insights into how energy is being used and the factors influencing consumption.
The study, led by Dr Andy Lewry, BRE's principal consultant, involved:
- Analysing existing cooling demand and consumption data.
- Assessing air conditioning inspection reports and energy performance certificates.
- Reviewing literature on trends in air conditioning usage and the possible future impacts of new technology.
- Developing procedures to extend the scope of DECC’s product policy model.
The main findings include:
- Cooling in air conditioning systems may account for around a tenth of total UK electricity consumption.
- Heat-waves are becoming more frequent across the UK, and in the South-East of England the number of heat-wave days per year has increased from 5 in 1961 to 17 in 2003.
- The proportion of buildings with air-conditioning is increasing. The study estimates that, in 2012, some 65% of UK office space and 30% of UK retail space was air-conditioned.
- The study estimates that cooling in offices typically uses around 40 kWh/m2 per year.
- Air conditioning is frequently used even when buildings are unoccupied, for example in the evenings and over the weekends.
- The analysis of Energy Performance Certificates (EPCs) indicates that more than half of all air conditioning systems in the UK are split systems. Although only 10% of EPCs have AC recommendations; these mostly relate to more efficient equipment, including variable speed drives, and reducing air leakage from ductwork
- An analysis of the recommendations in air conditioning inspection reports, reveals that they tend to be generic with the focus on improving controls and maintenance.
- Recommendations for updating the key inputs into DECC's product policy model of air conditioning electricity demand, and the development of an algorithm to estimate peak and monthly demand to supplement it.
BRE has also put together a dissemination plan aimed specifically at air-conditioning designers and technicians, building managers and smart system designers
The full report with appendices is freely-available here.
[edit] Related articles on Designing Buildings Wiki
- Air conditioning.
- Air conditioning inspection.
- BRE articles on Designing Buildings Wiki.
- Cooling systems for buildings.
- Energy performance certificates.
- Evaporative cooling.
- French air-conditioning market due to soar to new levels
- Global Air Conditioning Study 2016.
- HVAC.
- Underfloor air conditioning at London Grade II listed landmark.
- Workplace air conditioning.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Why being a mentor can help your career.
Channel 4 broadcaster to host 125th anniversary ceremony.
Listed structures on the rail network
Heritage interests and operational requirements must be balanced.
Historic England publishes research into embodied carbon when retrofitting traditional buildings.
New Prime Minister delivers on ECA call for cut in electricity costs.
CIOB reacts to the announcement of Andy Burnham as Prime Minister.
Heritage and conservation science workforce survey - Have your say.
England's Suburbs 1820-2020. Book review.
New, more proportionate and targeted approach for higher-risk building assessments.
Government brings British Steel into public ownership.
UKCW Birmingham returns with bold new theme and focus.
New guidance published on competence requirements for self-certification schemes.